30kW generator,32kW generator,33kW generator,34kW generator,35kW generator,36kW generator,37kW generator,38kW generator,40kW generator,42kW generator,45kW generator,48kW generator,50kW generator
30-50kw generators
30kVA generator,32kVA generator,33kVA generator,35kVA generator,37kVA generator,38kVA generator,40kVA generator,44kVA generator,45kVA generator,50kVA generator



What are ELECPRIME 30–50 kW Generator Sets?
ELECPRIME manufactures and assembles 30-50kW diesel generator sets using engines from renowned brands such as Cummins, Perkins, Baudouin, Weichai, Yuchai, Ricardo, Kubota, and Yanmar, and alternators from Stamford, Leroy Somer, Mecc Alte, and Marathon, along with Deep Sea, SmartGen, and ComAp control systems. These sets are available in silent, open-type, and trailer-mounted configurations, equipped with Automatic Transfer Switch (ATS) and Automatic Voltage Regulator (AVR) technology.
The 30-50kW generator set is one of the most commonly used power ranges in commercial, agricultural, and light industrial applications, offering stable voltage output and excellent fuel economy.
Contact us anytime; ELECPRIME provides reliable backup and primary power solutions.


Quality of ELECPRIME 30-50kW generator sets
ELECPRIME generators use industrial-grade engines with a long service life.
They offer more stable voltage and frequency when the load changes. All products are compatible with Automatic Transfer Switches (ATS) for automatic start-up and switching of the generator set. Voltage and frequency can be flexibly customized. Options include soundproof enclosures, rain covers, etc. Global warranty and global spare parts supply are available.
Equipped with a highly efficient and energy-saving operating system, they effectively reduce operating costs and are particularly suitable for standby or primary continuous operation.

ELECPRIME 30–50 kW Product Models
















Features of ELECPRIME 30-50kW Generator Sets
Each generator should undergo voltage testing, frequency testing, load testing, insulation testing, ATS simulation testing, emergency shutdown testing, and final visual inspection before shipment.
Cummins 30-50kW
Industrial generator with a mature design, capable of continuous operation and harsh conditions, strong load adaptability, high reliability, easy maintenance, long service life, and ample global spare parts supply.
Perkins 30-50kW
Features high transient response capability, excellent fuel economy, smooth operation, low noise, and low maintenance costs. Suitable for main/standby power supply projects requiring long-term operation or frequent starts.
Baudouin 30-50kW
Small to medium power generator set, high cost-performance ratio, simple maintenance, mainly used in residential, commercial, small factory, communication base station, and light outdoor engineering projects.
Weichai 30-50kW
Reliable performance, strong load adaptability, industrial-grade diesel generator, very low maintenance cost, particularly suitable for generator rental and engineering projects, strong continuous operation capability.
Yuchai 30-50kW
A high-end Chinese generator set with strong load adaptability. It adopts an optimized combustion chamber design and efficient fuel injection technology, resulting in excellent overall performance.
Kubota 30-50kW
A globally renowned industrial engine manufacturer with extremely high competitiveness in generator sets, construction machinery, and agricultural equipment. It features a compact structure and excellent fuel economy.
Yanmar 30-50kW
Employing Japanese engineering technology, it is typically used in residential backup power, communication base stations, data centers, small factories, agriculture, and the rental market.
Ricardo 30-50kW
Featuring Ricardo design and technology, it boasts high combustion efficiency and is commonly used as a backup power source. It offers excellent value for money and can be configured with an ATS (Automatic Power Supply) and intelligent control systems.
ELECPRIME 30-50kW Generator Sets FAQ
What can a 30kW diesel generator power?
The ELECPRIME 30kW generator set can provide 37.5kVA of power, typically powering lighting systems, air conditioning, refrigerators, water pumps, security systems, computers, network equipment, and various industrial tools simultaneously. It is an ideal backup power option for farms, workshops, and residences.
A single 30kW generator set can typically power 20 computers, lighting systems, network equipment, and multiple air conditioners simultaneously. In agricultural applications, it can meet the power needs of water pumps, ventilation equipment, and automated equipment. On construction sites, it can simultaneously power welding machines, compressors, and portable tools.
What can a 50kW diesel generator run?
A 50kW generator can power lighting systems, HVAC equipment, water pumps, elevators, refrigeration systems, computers, communication equipment, and production machinery.
It is typically used as a primary or backup power source for small factories, office buildings, hotels, supermarkets, construction sites, farms, and medical institutions.
At 70% load, the ELECPRIME 50kW generator consumes approximately 8 liters of fuel per hour, resulting in low long-term operating costs.
How do I choose between a 30kW and a 50kW generator?
A 30kW generator is typically suitable for small businesses, farms, small factory workshops, and residential backup power. It offers advantages such as low fuel consumption, low purchase cost, and low maintenance costs.
A 50kW generator is more suitable for large offices, commercial buildings, medium-sized manufacturing workshops, and applications where multiple motors or air conditioning systems operate simultaneously.
It is recommended to keep the generator set’s load between 60% and 80%. If your budget allows, we suggest prioritizing a 50kW generator set.
Is a 30kW generator enough for a small factory?
A 30kW generator can typically power lighting systems, office equipment, compressors, ventilation systems, and some production equipment. If you want to choose a 30kW generator set, you need to calculate the total power consumption of your factory.
Among our global customers, some light manufacturing plants, furniture factories, and small processing plants operate normally using 30kW generators. If your 30kW generator set needs to run continuously and your total power consumption is less than 25kW, then a 30kW generator is sufficient. Otherwise, you will need to purchase a larger power generator set.
Can a 50kW generator power an entire office building?
Typically, a 50kW diesel generator can power an entire office building and serve as a backup power source. Office loads usually include lighting, computers, printers, network equipment, security systems, elevators, HVAC systems, and communication infrastructure.
A 50kW generator can usually meet the power needs of these critical loads. It also needs to be equipped with an Automatic Power Supply (ATS) system and a soundproof enclosure to ensure automatic power restoration after a power outage.
How much fuel does a 30kW diesel generator consume per hour?
When operating the ELECPRIME 30kW generator set, we recommend keeping the load between 70% and 80% to effectively improve fuel efficiency and extend generator life. Prolonged operation with excessively low or high loads can damage the generator. At 25% load, fuel consumption is typically around 3.5L/hour. At 50% load, fuel consumption is typically around 5L/hour. At 75% load, fuel consumption is approximately 6.5L/hour, while at 100% full load, fuel consumption can reach 8L/hour.
How much fuel does a 50kW generator use at full load?
At 25% load, a 50kW generator consumes approximately 5 liters of fuel per hour. At 50% load, fuel consumption typically increases to 6.5 liters per hour. At 75% load, fuel consumption is approximately 8 liters per hour. At full load, fuel consumption is approximately 11 liters per hour.
However, fuel quality, altitude, ambient temperature, and maintenance schedules can affect combustion efficiency and increase fuel consumption.
Clogged air and fuel filters, and poor injector performance can also significantly increase fuel consumption. Improving fuel efficiency through appropriate configuration and regular maintenance can help reduce fuel consumption.
Which 30kW–50kW generator brand has the best fuel efficiency?
Perkins, Kubota, Yanmar, Cummins, and Baudouin all offer excellent fuel economy.
Perkins generators boast high fuel efficiency and relatively low operating costs. Kubota engines are compact, fuel-efficient, and highly reliable. Yanmar generators feature an optimized combustion chamber design for high combustion efficiency, reducing fuel consumption while increasing lifespan. Cummins is one of the world’s most popular generator brands, known for its durability, extensive after-sales support, and ample spare parts supply. In recent years, Baudouin has gained significant attention for its powerful performance, while also demonstrating good fuel economy in industrial applications.
How much does it cost to run a 50kW diesel generator for 24 hours?
The cost of operating a 50 kW diesel generator 24 hours a day depends primarily on fuel consumption and local diesel prices. Typically, a 50 kW generator operating at about 75% load consumes approximately 8-11 liters of diesel per hour. Over 24 hours, total fuel consumption could be between 192 and 264 liters. If diesel prices are $1 per liter, the daily fuel cost would be approximately $192 to $264.
Fuel costs are only one part of the total operating cost. Maintenance, oil, filters, coolant, regular servicing, and depreciation costs should also be considered.
Load has a significant impact on operating costs. A generator operating at 40-50% load may consume less fuel. Properly configuring a generator can reduce long-term operating costs compared to operating it near full load.
Which 30-50kw generator brand offers the lowest maintenance cost?
For generator sets ranging from 30kW to 50kW, brands with simple engine designs, readily available spare parts, and low maintenance costs are generally preferred. Statistics show that Cummins, Perkins, Kubota, Yanmar, and Weichai are typically considered to offer excellent value for money.
Cummins generators are technologically mature, reliable, durable, and have low maintenance costs. Perkins generators are also highly regarded. Kubota generators perform exceptionally well in commercial and agricultural applications. Yanmar generators offer outstanding durability and fuel efficiency. Weichai has readily available and relatively inexpensive spare parts, resulting in a lower overall operating cost.
Can a 50kW diesel generator be used as a prime power source?
Yes, the ELECPRIME 50kW generator can be used as a primary power source and operate under varying load conditions. It can run continuously for 24 hours when the load is maintained at around 70%.
Typically, the 50kW generator set has a 10% overload capacity; it is recommended that overload conditions not exceed 1 hour.
The primary generator requires maintenance based on operating hours. The engine oil, fuel filter, and air filter must be changed every 250 to 500 hours of operation.
If your 50kW generator operates below 30% load for extended periods, the generator set’s lifespan will be reduced, and periodic load tests should be performed.
Are 30kW generators suitable for agricultural irrigation systems?
Yes, the ELECPRIME 30kW generator is widely used in agriculture to provide power for farmland irrigation.
The starting current of induction motors used in agricultural production is much higher than the current under standard operating conditions. Therefore, we recommend using a 30kW generator only to start a 10 to 15 horsepower water pump. If you have a frequency converter installed, you can effectively reduce the starting current of the water pump, allowing you to start a 20 or 25 horsepower water pump motor.
What industries commonly use 50kW diesel generators?
A 50kW generator can output 62.5 kVA of three-phase power, making it a versatile medium-sized main power unit.
On commercial construction sites, a 50kW mobile generator can provide immediate power for municipal projects.
A 50kW generator equipped with an ATS (Automatic Power Supply) system and a large-capacity fuel tank can provide continuous power to telecommunications infrastructure. Small businesses and industries find the 50kW generator well-suited for their needs. In the event of grid failures, the 50kW generator can precisely take over the load, ensuring stable production operations.
Can a 50kW generator support construction site equipment?
Yes, a properly configured 50kW generator set can simultaneously power multiple heavy tools, temporary site infrastructure, and on-site office areas.
For optimal operation on construction sites, a 50kW generator set requires professional and standardized configuration. The trailer-mounted generator needs a robust and durable trailer chassis; a soundproof enclosure constructed from high-strength steel; and a multi-voltage selector switch that allows for quick switching of output voltage modes to meet the power needs of different equipment.
Can a 30kW or 50kW generator operate in parallel with other generators?
Yes, whether it’s a 30kW or 50kW generator, as long as it’s equipped with an intelligent parallel controller and electronic speed governor, it can operate in parallel with other generators.
If your critical equipment requires 50kW of load power, using two 50kW generator sets in parallel ensures operational continuity. Even if one generator set fails, the other can still handle the full load.
In a parallel system of 50kW generator sets, if the load is low, the control system will automatically shut down the other generators, operating only one generator set to avoid power waste.
What voltage and frequency options are available for 30kW–50kW generators?
ELECPRIME 30kW-50kW industrial generator sets support both single-phase and three-phase configurations, with frequencies including 60Hz (primarily for North America) and 50Hz (primarily for Europe, Asia, and Africa).
110/240V Single-phase configuration: Typically used for residential backup power, small offices, and construction site trailers.
220/480V Three-phase configuration: Typically used in manufacturing, agricultural irrigation pumps, and heavy construction equipment. It is the standard configuration for industrial power supply, minimizing current load and resulting in minimal losses during long-distance transmission.
How noisy is a 50kW silent diesel generator?
The ELECPRIME 50kW silent diesel generator set typically exhibits a noise level of 65 dB(A) – 70 dB(A) when operating at full load and measured at a distance of 7 meters.
A super silent enclosure is also available, with noise levels typically below 65 dB(A). Our silent enclosure utilizes sound-absorbing foam, is equipped with sound-absorbing baffles and louvers, and uses S-shaped intake and exhaust baffles to guide airflow, reducing generator set noise.
How often should a 30kW or 50kW diesel generator be serviced?
For 30kW or 50kW diesel generators, maintenance must be performed based on operating hours or daily schedule, whichever comes first. For standby generator sets, a routine oil and filter change and operational test is typically required every 250 to 500 hours of operation, or at least annually.
For primary generator sets, drain and change the oil, replace the oil filter, replace the primary and secondary fuel filters, and check or replace the air filter every 250 to 500 hours of operation.
Check for radiator blockage, test the coolant antifreeze concentration, and check the drive belt tension, etc.
What is the average lifespan of a 50kW diesel generator?
ELECPRIME’s 50kW diesel generator sets, when regularly maintained and operated under suitable load conditions, typically have an average service life of 20,000 to 30,000 hours.
Standby generator sets can easily last 20 to 30 years.
However, if a unit is used as the main power source and operates continuously in harsh industrial environments, its service life is reduced to approximately 6 years.
What warranty is typically provided for 30kW–50kW generator sets?
ELECPRIME’s standard warranty period for primary 30kW to 50kW diesel generator sets is typically 1 to 2 years or 1,000 to 2,000 operating hours, whichever comes first.
For standby generator sets, the warranty period is 24 months or 2,000 operating hours. Some brands offer extended warranties of up to 5 years (60 months), but the generator set must undergo certified annual maintenance as required.
Consumable parts and maintenance items are not covered by the warranty. These include engine oil, coolant, fuel filter, air filter, V-belt, fuses, and starter battery.
Damage to the generator set due to improper installation, improper operation, or failure to perform scheduled maintenance is not covered by the warranty.
How can overseas customers obtain spare parts and after-sales support?
1. When your generator set malfunctions, send the generator nameplate, fault code, and video. ELECPRIME’s technical engineers will remotely troubleshoot potential causes such as wiring, fuel injection, filters, and controllers, and provide repair guidance.
2. If the malfunction is caused by the engine, you can enjoy official after-sales service at your local service center.
3. Replacement parts will be sent to you via international express, air freight, or sea freight.
4. For large-scale power projects experiencing problems within the warranty period, ELECPRIME will dispatch technical engineers to the site for repairs. ELECPRIME will cover round-trip airfare and labor travel expenses. If the problem occurs outside the warranty period, the customer will bear the relevant costs, but ELECPRIME will still provide technical support and repair solution guidance.
Which is the best 50kW diesel generator for industrial use?
ELECPRIME typically combines Cummins or Perkins engines with Stanford generators and deep-sea electronic controllers. This combination is the best-selling and has received consistent praise from customers.
The Cummins 50kW generator set features a powerful 4-cylinder engine with excellent load capacity, while the Perkins 50kW industrial configuration offers extremely high cost-effectiveness.
Both the Stanford generator and the deep-sea electronic controller are world-renowned brands, known for their stable and reliable quality and lifespan well over 20 years.
Cummins vs Perkins 50kW generator
If you need a highly integrated, technologically advanced 50kW generator with excellent load-bearing capacity, choose Cummins. If your 50kW generator needs to handle different fuel qualities or be easy to repair and maintain, choose Perkins.
Cummins designs and manufactures its own engines, generators, and controllers. The highly integrated Cummins 50kW generator set responds quickly under heavy loads.
Perkins 50kW generator sets use an open architecture, typically assembled with Stanford alternators, Leroy-Somer alternators, and deep-sea controllers. This structure facilitates maintenance and offers high cost-effectiveness.
How long can a 50kW diesel generator run continuously?
Under normal circumstances, a 50kW generator set can run continuously for hundreds of hours, with the load maintained at 60%-80% of the generator’s rated power and proper ventilation. Even if a 50kW generator is connected to a high-capacity fuel supply system, it cannot run indefinitely. Industrial diesel generator sets need to be completely shut down every 250 to 500 hours of operation for oil, fuel filter, and oil filter replacement.
factory
For over 30 years, we have focused on the power industry, specializing in the production, sales, and after-sales service of generator sets and power-related facilities.
ELECPRIME is a professional manufacturer and seller of generator sets
a complete power solutions system provider
and an overseas sales and service provider of power solutions.

