  2. MTU generator

MTU Generators

Your reliable mtu generator sets

1. MTU generator sets feature enhanced power density, enabling them to deliver higher power output within a given physical footprint; they utilize mature high-pressure common rail technology, ensuring emission compliance with European and North American environmental standards.
2. MTU generator sets possess rapid start-up capabilities, typically reaching 100% of their rated output voltage and frequency within no more than 10 seconds following a cold start.
3. MTU generator sets are equipped with a proprietary intelligent electronic management system which, combined with advanced fuel injection technology, allows for the real-time monitoring and automatic adjustment of fuel injection volume for each cylinder of the Mercedes-Benz engine; this ensures exceptionally low fuel consumption and emission levels during operation.
4. MTU generator sets are constructed using high-strength alloy steel and mature casting processes, achieving exceptional durability and reliability while simultaneously minimizing the overall weight of the unit.
5. MTU generator sets adhere to extremely rigorous manufacturing standards, resulting in superior product quality and extended maintenance intervals.

    * Send us your question, we will respond in the next 24 Hours

    MTU generator models & power

    MTU 6R1600G10F Generator

    Standard Power: 275 kVA. Key Features: Inline 6-cylinder design, ensuring smoother operation and a lower failure rate—ideal for long-term, stable power supply.

      * Send us your question, we will respond in the next 24 Hours

      MTU 6R1600G20F Generator

      Standard Power: 312.5 kVA. Key Features: Extremely low long-term operating costs, highly suitable for primary power supply applications, and high power output.

        * Send us your question, we will respond in the next 24 Hours

        MTU 8V1600G10F Generator

        Standard Power: 362.5 kVA. Features: 8-cylinder V-configuration—more powerful and smoother than inline engines.Possesses an exceptionally long service life.

          * Send us your question, we will respond in the next 24 Hours

          MTU 8V1600G20F Generator

          Standard Power: 400 kVA. Features: MTU industrial generator set, high-pressure common rail fuel injection system, rapid start-up.100% Load Capacity

            * Send us your question, we will respond in the next 24 Hours

            MTU 10V1600G10F Generator

            Standard Power: 450 kVA. Key Features: A mainstay MTU generator set for medium-to-large-scale critical power applications, delivering smooth power output.

              * Send us your question, we will respond in the next 24 Hours

              MTU 10V1600G20F Generator

              Standard Power: 500 kVA. Key Features: Stable, high-load output capability; serves as a primary power source for industrial applications; features extended maintenance intervals.

                * Send us your question, we will respond in the next 24 Hours

                MTU 12V1600G10F Generator

                Standard Power: 600 kVA. Features: High-performance industrial generator set, exceptional reliability and response speed, intelligent control.

                  * Send us your question, we will respond in the next 24 Hours

                  MTU 12V1600G20F Generator

                  Standard Power: 660 kVA. Key Features: Typically utilized in power supply scenarios characterized by severe load fluctuations or the requirement for long-term continuous operation.

                    * Send us your question, we will respond in the next 24 Hours

                    MTU 12V2000G65 Generator

                    Standard Power: 800 kVA. Key Features: Exceptional durability and extended overhaul intervals; rapid startup and load acceptance; low vibration and low noise levels.

                      * Send us your question, we will respond in the next 24 Hours

                      MTU 16V2000G25 Generator

                      Standard Power: 910 kVA. Features: Intelligent load distribution and fault diagnosis capabilities, and exceptional single-step load acceptance capacity.

                        * Send us your question, we will respond in the next 24 Hours

                        MTU 16V2000G65 Generator

                        Standard Power: 1000 kVA. Key Features: Deeply optimized for handling sudden load surges, delivering exceptional performance in precision manufacturing and critical medical environments.

                          * Send us your question, we will respond in the next 24 Hours

                          MTU 18V2000G65 Generator

                          Standard Power: 1125 kVA. Key Features: Typically employs an electronic unit pump system, offering exceptionally high reliability and adjust the fuel injection volume for each cylinder.

                            * Send us your question, we will respond in the next 24 Hours

                            MTU 12V4000G21R Generator

                            Standard Power: 1250 kVA. Key Feature: Exceptional service life—with proper maintenance, the interval between major overhauls can exceed 30,000 hours.

                              * Send us your question, we will respond in the next 24 Hours

                              MTU 12V4000G23R Generator

                              Standard Power: 1375 kVA. Features: Excellent fuel economy and superior cold-start performance, with reinforced design for all components.

                                * Send us your question, we will respond in the next 24 Hours

                                MTU 12V4000G23 Generator

                                Standard Power: 1500 kVA. Features: Mature technology and high reliability, capable of sustaining extended periods of full-load operation and heavy-duty loads.

                                  * Send us your question, we will respond in the next 24 Hours

                                  MTU 12V4000G63 Generator

                                  Standard Power: 1800 kVA. Key Features: MTU’s largest 12-cylinder generator set, delivering an output power that exceeds that of some 16-cylinder generator sets.

                                    * Send us your question, we will respond in the next 24 Hours

                                    MTU 16V4000G23 Generator

                                    Standard Power: 2150 kVA. Key Features: Within the high-load range of 75% to 100%, fuel conversion efficiency is exceptionally high, resulting in very low fuel consumption.

                                      * Send us your question, we will respond in the next 24 Hours

                                      MTU 16V4000G63 Generator

                                      Standard Power: 2500 kVA. Key Features: Equipped with a high-power 20-cylinder engine, it demonstrates exceptional stability when handling large-scale IT loads or the startup of heavy-duty motors.

                                        * Send us your question, we will respond in the next 24 Hours

                                        MTU 20V4000G23 Generator

                                        Standard Power: 2500 kVA. Key Features: Equipped with a high-power 20-cylinder engine, it demonstrates stability when handling large-scale IT loads or the startup of heavy-duty motors.

                                          * Send us your question, we will respond in the next 24 Hours

                                          MTU 20V4000G63 Generator

                                          Standard Power: 2912.5 kVA. Key Features: Well-suited for application environments involving heavy server loads, precision instruments, or large-scale variable-frequency equipment.

                                            * Send us your question, we will respond in the next 24 Hours

                                            MTU 20V4000G63L Generator

                                            Standard Power: 3125 kVA. Features: An MTU diesel generator set delivering maximum power, featuring a long-stroke piston design that provides substantial low-end torque.

                                              * Send us your question, we will respond in the next 24 Hours

                                              MTU Generator Applications

                                              As a high-end diesel generator set, MTU is typically deployed in scenarios where power interruptions are unacceptable and reliability requirements are extremely stringent.

                                              1. Global Data Centers

                                              2. Critical Healthcare Facilities

                                              3. High-Traffic Transportation Hubs

                                              4. Intelligent and Automated Factories

                                              5. Onshore and Offshore Drilling Platforms

                                              6. Communication Base Stations and Network Equipment Rooms

                                              7. Military Facilities

                                              8. Municipal Power Station Projects

                                              The MTU generator sets manufactured and assembled by ELECPRIME are powered by MTU engines supplied by Rolls-Royce (China). Adhering to globally uniform production standards, these MTU engines—manufactured by Rolls-Royce (China)—are indistinguishable from their German-imported counterparts in terms of technical specifications, core components, and quality control.
                                              The MTU generator sets provided by ELECPRIME undergo the exact same rigorous testing protocols as the German-imported units—including load testing, emissions testing, and durability testing. We are able to provide original manufacturer test reports and global warranty certificates, offering exceptional value for money.

                                                * Send us your question, we will respond in the next 24 Hours

                                                ELECPRIME provides flexible, efficient, and project-tailored custom solutions for MTU generator sets.
                                                1. Customization of power ranges and various voltage levels, as well as dual-frequency switching (50Hz/60Hz) or multi-unit parallel operation configurations.
                                                2. Customization of generator set structures (Open Type, Silent Type, Super Silent, Containerized Power Station, Mobile Trailer, etc.).
                                                3. Support for configuring HMG, Deep Sea (DSE), and ComAp control systems, as well as various intelligent parallel control systems.
                                                4. Customization options for ATS automatic transfer systems, parallel cabinets, remote monitoring systems, automatic refueling systems, and more.
                                                5. Custom-engineered MTU generator sets designed specifically for harsh environments, such as regions with high temperatures, high altitudes, high humidity, or dusty operating conditions.

                                                  * Send us your question, we will respond in the next 24 Hours

                                                  MTU generators are engineered for high reliability and continuous-duty applications, adhering to rigorous manufacturing standards. The engines are constructed using high-strength alloy steel to ensure fault-free operation over extended periods. Leveraging Germany’s precision manufacturing heritage, MTU generator sets exhibit minimal operational fluctuation and deliver exceptionally rapid load response; even under the impact of heavy load transients, voltage and frequency recovery times are remarkably brief. Furthermore, MTU features a highly mature high-pressure common rail fuel injection system, resulting in minimal vibration and low fuel consumption during operation.

                                                    * Send us your question, we will respond in the next 24 Hours

                                                    MTU generator sets incorporate high-performance materials and advanced electronic control systems, demonstrating exceptional adaptability to harsh operating environments. Feedback from customers in the Middle East, Africa, and desert regions indicates that MTU generator sets are highly resistant to overheating during prolonged operation and maintain stable power output even under high-temperature conditions. Furthermore, these units sustain robust power output in low-oxygen environments characteristic of high altitudes. By incorporating multi-stage air filtration systems and enhanced air intake protection, MTU generator sets also exhibit strong resilience in dusty environments.

                                                      * Send us your question, we will respond in the next 24 Hours

                                                      Generator set

                                                      engine parameters

                                                      Generator model

                                                      Power(1500RPM/50HZ)

                                                      Size
                                                      L×W×H(mm)

                                                      Weight(kg)

                                                      Engine Model

                                                      Pime/standby
                                                      Power(kw)

                                                      Cylinder

                                                      Bore/stroke(mm)

                                                      Displacement

                                                      EPBCA220 220kw 275kva 2500×890×1350 2400 6R1600G10F 249 6 122×150 8.2
                                                      EPBCA250 250kw 312.5kva 2500×890×1350 2450 6R1600G20F 274 6 122×150 8.2
                                                      EPBCA290 290kw 362.5kva 2600×900×1500 2500 8V1600G10F 325 8 122×150 11.6
                                                      EPBCA320 320kw 400kva 2600×900×1500 2550 8V1600G20F 358 8 122×150 11.6
                                                      EPBCA360 360kw 450kva 3000×1200×1700 3100 10V1600G10F 407 10 122×150 13.5
                                                      EPBCA400 400kw 500kva 3320×1350×1850 4000 10V1600G20F 448 10 122×150 17.5
                                                      EPBCA480 480kw 600kva 3500×1350×1850 4350 12V1600G10F 524 12 122×150 21
                                                      EPBCA528 528kw 660kva 3500×1350×1850 4350 12V1600G20F 576 12 122×150 21
                                                      EPBCA520 520kw 650kva 3500×1350×1850 4350 12V2000G25 580 12 130×150 23.88
                                                      EPBCA640 640kw 800kva 3930×1580×2100 5155 12V2000G65 695 12 130×150 23.88
                                                      EPBCA728 728kw 910kva 4380×1580×2250 6190 16V2000G25 810 16 130×150 31.84
                                                      EPBCA800 800kw 1000kva 4220×1580×2250 6590 16V2000G65 890 16 130×150 31.84
                                                      EPBCA900 900kw 1125kva 4500×1910*2430 7225 18V2000G65 1000 18 130×150 35.82
                                                      EPBCA1000 1000kw 1250kva 4050×1670×23B0 8775 12V4000G21R 1102 12 165×190 48.7
                                                      EPBCA1100 1100kw 1375kva 4150×1670×23B0 9820 12V4000G23R 1205 12 170×210 57.2
                                                      EPBCA1200 1200kw 1500kva 4250×1670×23B0 10110 12V4000G23 1420 12 170×210 57.2
                                                      EPBCA1440 1440kw 1800kva 4250×1670×2380 10590 12V4000G63 1575 12 170×210 57.2
                                                      EPBCA1720 1720kw 2150kva 4750×1670×2380 12430 16V4000G23 1798 16 170×210 76.3
                                                      EPBCA1800 1800kw 2250kva 4950×1670×23B0 13430 16V4000G63 1965 16 170×210 76.3
                                                      EPBCA2000 2000kw 2500kva 5500×1620×2600 15890 20V4000G23 2200 20 170×210 95.4
                                                      EPBCA2330 2330kw 2912.5kva 5600×1620×2600 16400 20V4000G63 2420 20 170×210 95.4
                                                      EPBCA2500 2500kw 3125kva 5700×1620×2600 16910 20V4000G63L 2590 20 170×210 95.4

                                                      factory

                                                      ELECPRIME manufactures MTU generator sets by combining genuine MTU engines with locally assembled systems. With 30 years of experience in generator set production, our facility features highly refined assembly processes, rigorous testing protocols, and robust customization capabilities.

                                                      Contact Us

                                                        * Send us your question, we will respond in the next 24 Hours

                                                        ELECPRIME mtu generator set FAQ guide

                                                        When selecting an MTU generator set, it is typically essential to consider key factors such as performance stability, fuel efficiency, intended applications, configuration options, and after-sales support. To assist you in gaining a more comprehensive understanding of our products, we have compiled the following list of Frequently Asked Questions (FAQs).
                                                        These questions are drawn from genuine inquiries raised by customers worldwide during the selection, procurement, and operational phases, enabling you to quickly determine whether an MTU generator set is the right fit for your specific project requirements.
                                                        We hope this FAQ guide serves as a practical reference to help you make your purchasing decisions more efficiently.

                                                        How to Select the Appropriate Power Rating for an MTU Generator Set?

                                                        The capacity of MTU generators is typically expressed in kVA. The calculation formula is: kVA = kW ÷ Power Factor (typically 0.8).
                                                        When selecting a power rating, it is advisable to allow for a sufficient safety margin; failure to do so poses risks during long-term operation. For standard projects, a margin of 10%–20% is recommended, while for applications involving high-impact loads, a margin of 20%–30% is suggested.
                                                        The power output of MTU generators may decrease in various environmental conditions—such as high altitudes (>1000m), high temperatures, or dusty environments. In such cases, it is typically necessary to select a generator set with a higher power rating or to apply power correction adjustments.

                                                        What key parameters should be considered when selecting an MTU generator set?

                                                        1. Consider the intended application of the MTU generator set; typically, there are three categories: Standby Power, Prime Power, and Continuous Power.
                                                        2. Determine the required voltage and frequency based on the region where the MTU generator set will be deployed. Common voltages include 230V, 380V, 400V, 415V, and 440V; frequencies are typically 50Hz or 60Hz; and the configuration is usually three-phase.
                                                        3. Consider the specific application scenario of the generator set—such as data centers, hospitals, or telecommunication base stations—to determine whether it will be subject to impact loads.
                                                        4. Additionally, consider the operating environment of the MTU generator set to determine whether supplementary configurations are required or if power output adjustments are necessary.

                                                        What is the fuel consumption rate of MTU generator sets?

                                                        Under typical conditions, the fuel consumption rate of MTU generator sets is approximately 195–205 g/kWh at 100% load, and 200–210 g/kWh at 75% load. At loads below 50%, this figure may rise to 210–230 g/kWh. The fuel consumption rate of MTU sets is at its lowest when operating under standard ambient temperatures and at a load of 70%–80%; among high-end diesel generator sets, they stand as a prime example of both high reliability and low fuel consumption.

                                                        What advantages do MTU generator sets offer compared to other brands?

                                                        At equivalent power outputs, MTU generator sets consume approximately 10% less fuel; furthermore, for a given physical size, they deliver higher power output.
                                                        Under sudden load application, voltage and frequency fluctuations remain minimal.
                                                        Adhering to rigorous German precision manufacturing standards, these units feature low noise and vibration levels, ensuring exceptional reliability.
                                                        Moreover, as their design is optimized for long-term continuous operation, they boast extended maintenance intervals and a long service life, making them particularly well-suited for critical power applications such as data centers and telecommunication base stations.

                                                        In what aspects do the technical advantages of MTU engines manifest?

                                                        MTU generator sets feature a comprehensive and advanced technical framework, primarily excelling in combustion control, structural design, and system integration.
                                                        1. The high-pressure common rail fuel injection system enables multi-injection control, resulting in more complete combustion and lower fuel consumption.
                                                        2. The advanced turbocharging and air intake management system enhances intake efficiency and boosts torque at low engine speeds.
                                                        3. The intelligent electronic control system monitors operating conditions in real-time, automatically adjusting parameters such as fuel injection volume and engine speed.
                                                        4. Exceptional transient response capabilities allow for the rapid recovery of voltage and frequency in the event of load fluctuations.
                                                        5. The use of high-strength materials enhances the durability of the generator sets, making them ideally suited for long-term operation under heavy-load conditions.

                                                        What are the noise levels of MTU generator sets?

                                                        Typically, the noise level of an open-frame MTU generator set is approximately 110 dB(A).
                                                        At a distance of 7 meters, the noise level for a standard soundproof enclosure is around 75 dB(A), while that of a super-silent enclosure is approximately 65 dB(A).
                                                        MTU possesses distinct technical advantages in noise control; by utilizing a V-type structural design and a high-pressure common rail injection system, the company effectively minimizes mechanical vibration and noise.
                                                        Furthermore, MTU’s high-quality silencers and superior airflow duct design contribute significantly to noise reduction.

                                                        Can an MTU generator set start normally in low-temperature conditions?

                                                        With a standard configuration, the unit can typically start normally at temperatures above -10°C.
                                                        However, when the ambient temperature drops below -10°C, starting becomes significantly more difficult; at temperatures below -20°C, the installation of a low-temperature auxiliary system is mandatory.
                                                        By incorporating a coolant heating system and an oil heating system, the unit can start normally at temperatures below -20°C—or even as low as -30°C.
                                                        In summary, MTU generator sets are fully capable of starting normally in low-temperature environments, provided they are equipped with the appropriate preheating and auxiliary systems. With a comprehensive low-temperature configuration, the unit can operate stably for extended periods in environments ranging from -20°C to -30°C.

                                                        Do MTU generator sets support intelligent control systems and remote monitoring?

                                                        Standard-configured MTU generator sets feature an integrated intelligent control system capable of performing functions such as automatic start-up and shut-down, automatic load transfer, parallel synchronization control, and automatic switching between the generator set and utility power.
                                                        Furthermore, the MTU control system supports remote communication and monitoring capabilities, allowing for the real-time monitoring of critical data—including voltage, current, power, frequency, engine speed, fuel consumption, fuel level, water temperature, and oil pressure. This data can be centrally managed via network transmission, enabling remote troubleshooting and problem resolution.

                                                        Is it possible to customize specific voltages or frequencies based on project requirements?

                                                        MTU generator sets can be adapted to comply with the grid standards of various countries and support multiple voltage configurations. They can also be equipped with a dual-frequency switching system.
                                                        However, it is important to note that the voltage must be finalized either during the design phase or prior to factory shipment. Typically, a choice must be made between 50 Hz and 60 Hz; if a dual-frequency switching system is required, this requirement must be established during the generator set’s design phase.
                                                        MTU generator sets cannot be customized arbitrarily, as the specific customization standards vary depending on the power output of the unit.

                                                        Can MTU generator sets be equipped with an automatic refueling system?

                                                        The integrated control system included in the standard configuration of MTU generator sets is designed to interface seamlessly with an automatic refueling system, enabling functions such as low-fuel level alarms, automatic refueling triggers, and fault-interlock protection. This makes it ideally suited for scenarios requiring continuous operation—such as data centers, hospitals, mines, and telecommunication base stations.
                                                        When configuring an automatic refueling system, it is essential to prioritize comprehensive safety measures, including spill prevention, fire protection, backflow prevention, and emergency shut-off valves. This system is typically recommended for projects requiring extended generator operation, unmanned facilities, multi-unit parallel power stations, or projects located in remote regions.

                                                        What is the maintenance schedule for MTU generator sets?

                                                        The maintenance schedule for MTU generator sets is determined comprehensively based on accumulated operating hours, elapsed time intervals, and specific operating conditions.
                                                        Prior to each operation, it is necessary to check the oil and fuel levels, coolant level, and battery voltage, as well as to inspect the generator set for any leaks. Every 250 operating hours, checks should be performed on belt tension, fasteners, and similar components. Every 500 hours, the engine oil and oil filter must be replaced, and the cooling, intake, and exhaust systems should be inspected. Every 2,000 hours, the fuel filter is to be replaced, and the fuel injection system, turbocharger, and control system parameters should be inspected and calibrated. A major service is required every 5,000 hours

                                                        What is the typical service life of an MTU generator set, in hours?

                                                        Application Scenarios

                                                        Lifespan/hours

                                                        Explanation

                                                        Standard Service Life 20000 – 30000 hours Routine operating conditions + Regular maintenance
                                                        Optimized Service Life 30000 – 50000 hours Good maintenance + Reasonable load
                                                        Extremely Extended Service Life 50000 – 60000+ hours High-standard maintenance + Excellent operating conditions
                                                        Overhaul Cycle 30000 hours First major overhaul time
                                                        Ready to Restart After Overhaul Over 20000 hours After replacing key components

                                                        Are spare parts for MTU generator sets readily available?

                                                        MTU Generators maintains a comprehensive global network comprising over 1,500 service points. With three major logistics hubs established across Europe, the Americas, and Asia, most commonly used spare parts are available for immediate dispatch. When you require them, parts can be shipped within 24 to 48 hours in most regions.
                                                        Globally, supplies range from basic maintenance consumables to critical core components.
                                                        If your MTU generator set is a custom-built unit, it may require a specific production lead time; typically, such orders can be fulfilled within 60 days.

                                                        How can overseas customers receive MTU electricity after delivery?

                                                        Typically, after-sales service can be accessed through a global service network.
                                                        Customers may contact local authorized dealers or service providers, reach out to the official service network online, or call a regional service center.
                                                        After-sales services typically include installation and commissioning, routine maintenance, fault repair, and the supply of genuine spare parts.
                                                        MTU provides 24/7 global customer support.

                                                        What are the common faults in MTU generator sets?

                                                        Fault Category

                                                        Fault Symptoms:

                                                        Main causes:

                                                        Troubleshooting:

                                                        Starting system failure Failure to start Insufficient battery power / Loose wiring Inspect or replace the battery, tighten wiring.
                                                        Difficulty starting Low temperature / Fuel problems Activate the preheating system, change fuel.
                                                        Stalling after starting Unstable fuel supply Inspect fuel lines and filter.
                                                        Fuel system failure Insufficient power Clogged fuel filter Replace filter.
                                                        Abnormal fuel consumption Wearing fuel injectors Inspect or replace injectors.
                                                        Difficulty starting Fuel containing water or impurities Change fuel, clean fuel lines.
                                                        Cooling system failure Overheating Clogged radiator Clean radiator.
                                                        Insufficient coolant Leaking lines Inspect and repair leaks.
                                                        Temperature alarm Water pump failure Replace or repair water pump.
                                                        Lubrication system failure Low oil pressure Insufficient engine oil Top up engine oil.
                                                        Abnormal oil pressure Fuel pump failure Inspect or replace fuel pump.
                                                        Contaminated engine oil Long-term oil not changed Change engine oil regularly.
                                                        Electrical system failure No power output AVR failure Inspect or replace pressure regulator.
                                                        Unstable voltage Load fluctuation Optimize load configuration.
                                                        Abnormal frequency Unstable engine speed Inspect control system.
                                                        Intake and exhaust system failure Excessive black smoke Incomplete combustion Inspect fuel injection system.
                                                        White smoke Low temperature incomplete combustion Activate preheating system.
                                                        Power reduction Clogged air filter Clean or replace filter.
                                                        Operating abnormality Automatic shutdown Overload protection Reduce load.
                                                        Frequent alarms Large load fluctuation Optimize electrical system.
                                                        Power reduction Long-term low-load operation Increase load factor.
                                                        Control system failure Frequent alarms Sensor failure Replace sensor.
                                                        Abnormal data Communication problems Inspect wiring.
                                                        Unable to remotely monitor Network or module failure Inspect communication module.

                                                        Why choose an MTU generator set assembled by ELECPRIME?

                                                        By combining genuine MTU core engines with ELECPRIME’s expert system integration and assembly techniques, we ensure our generator sets deliver stable performance, lower failure rates, and highly efficient operation.
                                                        ELECPRIME goes far beyond simple component assembly; we engage in engineering-grade manufacturing. Our process features standardized production workflows, precision installation, and comprehensive system commissioning—including load testing, electrical performance testing, and continuous run testing.
                                                        Furthermore, ELECPRIME offers more than just MTU generator sets; we provide complete power solutions—such as multi-unit paralleling systems, ATS (Automatic Transfer Switch) systems, and grid integration solutions—to meet all your power requirements.